PRT-IO84-DIN
The Protege DIN Rail 8 Input/4 Output Expander provides the interface of up to 8 zone inputs and the control of 4 high current Form C relay outputs to the Protege system, an advanced technology security product providing seamless and powerful integration of access, security and building automation. The Input/Output Expander is designed for use with industry standard DIN Rail mounting.
Special Features
- Connect any combination of normally closed or normally open inputs, configurable per input
- Utilizes analog to digital processing with 5 over sampling
- 4 state input alarm using resistors to provide short, alarm, closed and tamper conditions
- 4 Form C relays capable of switching resistive loads up to 7 Amps
- High performance 32 Bit processor
- Designed for use with industry standard DIN Rail mounting
Technical Specifications
| DC Input Voltage | 11-14VDC |
| DC Output Voltage (DC IN Pass-Through) | 10.45-13.85VDC 0.7A (Typical) Electronic Shutdown at 1.1A |
| Operating Current | 80mA (typical) |
| Low Voltage Cutout | 8.7VDC |
| Low Voltage Restore | 10.5VDC |
| RS-485 | Isolated module network |
| Outputs | 4 FORM C Relays – 7A N.O./N.C. at 30 VAC/DC resistive/inductive |
| Inputs | 8 (10ms to 1hr input speed programmable) |
| Trouble Inputs | 16 |
| Dimensions (L x W x H) | 156.8 x 90 x 60mm (6.17 x 3.54 x 2.36″) |
| Weight | 290g (10.23oz) |
| Operating Temperature | -10° to 55°C (14° to 131°F) |
| Storage Temperature | -10˚- 85˚C (14˚ – 185˚F) |
| Humidity | 0%-93% non condensing, indoor use only (relative humidity) |
| Mean Time Between Failures (MTBF) | 587,177 hours (calculated using RFD 2000 (UTE C 80-810) Standard) |
Other Features
Power Supply
The Protege DIN Rail 8 Input/4 Output Expander operates from a 12VDC input. Ultra low current requirements ensure cost effective power distribution.
Connectivity and System Expansion
Expansion of the Protege system with local inputs and outputs allows convenient cost effective expansion and added benefit of:
> 8 inputs that can be used to perform any system alarm and automation functions
> 4 multiple function outputs for use in any programmable output entry, ideal for connection in an electrical switch room to control signage, lighting and building automation
> Address configuration is achieved using the address programming feature of the Protege System Controller
> Outputs can be configured to automatically turn on when powered up, on communication failure, or to resume previous state
Communication
Single RS-485 communication interface port used for all network communication functions and interconnection to other modules.
Upgradable Firmware
Utilizing the latest flash technology and high performance communication mediums, the firmware can be updated using the ICT Loadit utility over the Protege system module network.